Gas fired Hot water Boiler |
My Whole House Has No Heat |
|
|
Continuing from No
Heat
Page
Do you have no heat in the house? Read below to troubleshoot your problem.
First turn your thermostat ALL THE Way Up. "YES" ALL
THE WAY, As High As it will Go. If you have more then one turn them all up.
Now go to the boiler. Feel the pipe coming out of the
boiler (pipe may be very hot so be careful, A quick touch will tell you if it is
hot) scroll down to
continue.
Find a local Plumbing and Heating contractor
The pipe on the boiler is Hot.
Not finished
The pipe on the boiler is not hot
Not Started
|
The pipe on the boiler is Hot.
Ok Now check the gauge what is the
pressure showing. Note: you can not rely on the gauge it may be stuck. to test
for stuck gauge
click here
The gauge is showing more then 10 psi
Not Finished
The gauge is showing 0 psi
Finished
The gauge is showing more then 10 psi
If you have zone valves check to see if
they are open. All zone valves have some kind of lever you can slide to put the
zone valve on manual. Honeywell have a lever near the bottom of the zone valve ,
Taco have a lever along side the three screws that pulls down. if the lever can
be pushed from one end to the other with out much resistance it is open if there
is resistance they are closed.
My zone valves are open
not finished
My Zone valves are not open Not
started Note: to self. Why are zones not open?
I do not have zone valves.
Not Started
The gauge is showing 0 psi
your
fill valve
and or your
expansion tank
are bad or your water to
the boiler is off. get this fixed then purge your lines.
Once you have corrected the above issues. If you still are having problems start the trouble shooter again
Re Start Troubleshooter
|
My zone valves are open
Ok Now check the circulator pump. This can
get tricky. You may be able to hear the pump running (this does not
mean it is working correctly.) (Warning A Pump Can Be Hotter then the
pipes) You may Have to check to make sure power is going to the pump. remove
cover on pump and see if wires are hot. If you are not sure you can do this with
out getting shocked, STOP AND CALL A PROFESSIONAL!!!
Yes there is power getting to the pump
finished
No there is no power going to the pump
Finished
Yes there is power getting to the pump
Can you hear the pump running?
Yes I hear the pump running
Finished
No I can't tell if the pump Is running or
not. Finished
Yes I hear the pump running
Ok Just because you hear the pump running does not mean it is
working. but lets assume that it is for now.
First turn the power to the boiler off. and put all the zone valves to the
manual position. You should have some kind of set up like this.
Turn the valve
before the boiler drain off. Put a hose on the boiler drain and turn the boiler
drain on.
What is coming out of
the hose?
I got just a little bit of water then it
stopped Finished
Yes I am getting air and water out of the hose Finished
I am getting just water out of the hose.
Finished
No I can't tell if the pump Is running
or not.
Try turning the power on and off to see if there is a difference.
You should be able to hear it start and stop. Note If you have
Taco zone Valves it can take 2 full minutes for the pump to start.
Remember you said you have power to the pump. If you do not have power
to the pump you have made a wrong turn restart the
trouble shooter.
I do not hear any change
I hear a click but I do not hear the
pump.
Note: If you have Taco zone valves you may need to wait 2 minutes
before you hear any thing.
If you hear a click or not. If you have power to the pump and you can not hear it running it probably needs to be replaced please replace pump.
|
I got just a
little bit of water then
it stopped
Did the pressure gauge drop?
Yes it did drop
Finished
No the Pressure is still above 10 psi
Finished
No the Pressure is still above 10
psi
Before we make a mistake open the valve
you closed. Do you have water flowing out of the hose now?
Yes it Is Flowing Now Finished
No I got a little more water but it stopped.
Finished
Yes it Is Flowing Now
Ok make sure the zone valves are open
and there are no other valves on that loop closed.
If you are sure no other valves are closed and the zone valve is fully open, the line may be froze or broken under ground Stop And Call a plumber.
If you feel that this is not correct any want to ask me more about it Please call me Click Here or email me at tom@masterplumber.net please do not use this email address to ask plumbing or heating questions.
Click
here
to
ask
a
Plumbing
question
Click
here
to
ask
a
heating
question
|
I heard a difference when I turned the
power on and off (the pump is running)
I did not hear any change (your pump is bad.
click
here)
Ok your system was air locked. you need to remove the air from
all the zones.
click here
I am getting just water out of the
hose.
If you are getting a steady flow of water and it starts to get
hot, with out any bursts of air.
you are sure the valve before the boiler drain is closed,
You are sure you have 120 volts of power at the pump.
Your pump
is bad. click here
If after you have replaced your pump, You are still having problems, or if you would like to be sure before you replace the pump Please call Click Here Or email me at tom@masterplumber.net please do not use this email address to ask plumbing or heating questions.
Click
here
to
ask
a
Plumbing
question
Click
here
to
ask
a
heating
question
|
For help with any problem please use my
open dialog service
To contact me use this email
Tom@masterplumber.net
please
do
not
use
this
email
address
to
ask
plumbing
or
heating
questions.
Click
here
to
ask
a
Plumbing
question
Click
here
to
ask
a
heating
question
|