Once the cartridge is installed and flush with the brass base put the nut back on. tighten the nut as tight as you can by hand, you do not need to use a wrench to tighten the nut. With the nut in place you can slide the sleeve back into place If you have the chrome or equal handle make sure the with plastic insert is inside the sleeve

 